What it means
Maytag words F4E4 as a possible problem with the humidity thermistor or its wiring, the same cause as F3H. Reset at the breaker for one minute and monitor the microwave for one minute; schedule a technician if it returns.
Maytag microwave F4E4 / Sensors
Maytag words F4E4 as a possible problem with the humidity thermistor or its wiring, the same cause as F3H. Reset at the breaker for one minute and monitor the microwave for one minute; schedule a technician if it returns.
Also printed as F4E4
Maytag words F4E4 as a possible problem with the humidity thermistor or its wiring, the same cause as F3H. Reset at the breaker for one minute and monitor the microwave for one minute; schedule a technician if it returns.
Microwaves keep a charge when unplugged, so the casing stays shut.
F4E4 returns after the one-minute breaker reset.
Your Maytag to-do list, saved here on this device

Stop any sensor program, ventilate steam and let the cavity cool.

Turn the circuit breaker off for one minute, then back on, and monitor the oven for one minute as the page says.

F3H reads the same as F4E4; F3H1 says humidity sensor. Note which you saw.

F4E1 is the cavity temperature thermistor.
Do not open the microwave housing; thermistors, boards and wiring sit behind high-voltage parts.
Give us the model and the checks you have run, then open your request right here.
Book a visit

A rough sketch only, because a Maytag is laid out differently from model to model. Click a highlighted part to open its photo and the matching test.

Component reference
On a Maytag over-the-range microwave, F3H1 names the humidity sensor, while F3H and F4E4 name the humidity thermistor, and their wiring.
Read the definitionThere may be a problem with the humidity thermistor or the associated wiring. The page then lists the reset.
Read the supporting manualF3H prints the same sentence about the humidity thermistor. Maytag gives two codes for one named part.
Read the supporting manualF3H1 says humidity sensor, not thermistor.
Read the supporting manualF4E1 is next in the F4 list and names the cavity temperature thermistor.
Read the supporting manualManufacturer document
Maytag Product Help (producthelp.maytag.com)
dateModified 2021-04-29; PH 10364 / PH 10364 (over-the-range microwave)
Manufacturer document
Maytag Product Help (producthelp.maytag.com)
dateModified 2021-04-29; PH 10358 / PH 10358 (over-the-range microwave)
Manufacturer document
Maytag Product Help (producthelp.maytag.com)
dateModified 2021-04-29; PH 10357 / PH 10357 (over-the-range microwave)
Manufacturer document
Maytag Product Help (producthelp.maytag.com)
dateModified 2021-04-29; PH 10363 / PH 10363 (over-the-range microwave)
Product Help lists no models for this entry; the page covers the over-the-range microwave tree. Source: Product Help PH 10364, with the F3H, F3H1 and F4E1 pages.
Maytag prints no cause beyond the humidity thermistor or its wiring. If F4E4 came up during a sensor cooking program, tell us, but do not assume steam is the reason.
Not in the text. Both pages say there may be a problem with the humidity thermistor or the associated wiring and give the same one-minute reset, so they are two codes for one named part.
No. F4E9 names the Smart Pop control or its wiring, while F4E4 names the humidity thermistor. Check the last character of the code on your display.
Give us the microwave model, the exact code and the cooking program in use. Also tell us whether the breaker reset cleared the code.
Maytag codes, symptoms, parts and service
The Maytag over-the-range microwave entry for F4E1 names the cavity temperature thermistor or the wiring. Reset first, then call us in if the code keeps coming back.
If a Maytag microwave will not start, the display usually explains why: a door message, the LOC padlock icon, or Demo Mode. Reopen and reclose the door first, then check the lock and demo settings before you book a visit.
On a Maytag over-the-range microwave, F3H1 names the humidity sensor, while F3H and F4E4 name the humidity thermistor, and their wiring. The pages share one step: cut power at the breaker for 60 seconds, restore it, and see whether the code reappears within a minute.