What it means
Maytag words F3T3 as a possible problem with the hood temperature thermistor or its wiring. Reset at the breaker for one minute and monitor for one minute. If F3T3 returns, schedule a technician.
Maytag microwave F3T3 / Sensors
Maytag words F3T3 as a possible problem with the hood temperature thermistor or its wiring. Reset at the breaker for one minute and monitor for one minute. If F3T3 returns, schedule a technician.
Also printed as F3T3
Maytag words F3T3 as a possible problem with the hood temperature thermistor or its wiring. Reset at the breaker for one minute and monitor for one minute. If F3T3 returns, schedule a technician.
Unplug the microwave or switch off its breaker before any panel comes off, and never open the casing, because it holds charge.
F3T3 returns after the one-minute breaker reset.
Your Maytag to-do list, saved here on this device

This model line is a microwave and hood combination. Make sure the vent fan is not running against a blocked grease filter. That is our look, not a printed step.

Stop any cooking and let the unit cool.

Turn the circuit breaker off for one minute, then back on, and monitor the oven for one minute as the page says.

F3T2 is the convection thermistor, F3T4 the magnetron, F3T1 the user interface.
Do not open the microwave housing; thermistors, boards and wiring sit behind high-voltage parts.
Give us the model and the checks you have run, then open your request right here.
Book a visit


A rough sketch only, because a Maytag is laid out differently from model to model. Click a highlighted part to open its photo and the matching test.
There may be a problem with the hood temperature thermistor or the associated wiring.
Read the supporting manualF3T2 is the convection thermistor. F3T4 is the magnetron temperature thermistor.
Read the supporting manualF3T1 names the user interface thermistor.
Read the supporting manualMaytag prints no more than the part name and its wiring; it does not say where the thermistor sits.
Read the supporting manualManufacturer document
Maytag Product Help (producthelp.maytag.com)
dateModified 2021-04-29; PH 10361 / PH 10361 (over-the-range microwave)
Manufacturer document
Maytag Product Help (producthelp.maytag.com)
dateModified 2021-04-29; PH 10360 / PH 10360 (over-the-range microwave)
Manufacturer document
Maytag Product Help (producthelp.maytag.com)
dateModified 2021-04-29; PH 10362 / PH 10362 (over-the-range microwave)
Manufacturer document
Maytag Product Help (producthelp.maytag.com)
dateModified 2021-04-29; PH 10359 / PH 10359 (over-the-range microwave)
Product Help lists no models for this entry; the page covers the over-the-range microwave tree. Source: Product Help PH 10361, with the F3T2, F3T4 and F3T1 pages.
The page names a hood temperature thermistor and its wiring but does not mention the range below. Tell us whether the range was in use when the code appeared.
Maytag does not say. Test the fan only after the one-minute breaker reset, and tell us if it does not respond.
The page prints no cause. It lists the hood temperature thermistor or the associated wiring, so do not assume steam or heat from below is the reason.
Give us the microwave model, the exact code and whether the range below was in use. Also say whether the breaker reset cleared the code, even briefly.
Maytag codes, symptoms, parts and service
Maytag prints this code as F3.t2 in the page heading and words it as a possible problem with the convection thermistor or its wiring. Reset at the breaker for one minute; if it returns, schedule a technician.
If a Maytag microwave will not start, the display usually explains why: a door message, the LOC padlock icon, or Demo Mode. Reopen and reclose the door first, then check the lock and demo settings before you book a visit.
Book a diagnostic for your model, done at the machine.
Office details, and the entry information to pass along.