- F4 E3 and AF or Check Vent: clean the lint screen, check the vent run and the outside hood; the dryer keeps running. 12
- F4 E4 and L2: check both breakers, the 240-volt supply and the power cord, then pause for 5 minutes. 34
- F1 E1: 5 minute breaker pause. F3 E3, F4 E1 and F6 E1: one minute. 5679
- PF: hold Start to carry on, or press Power to dismiss it; after an outage, 5 minutes at the breaker. 8
- Clean the home venting once a year or two. 110
How do I sort a Maytag dryer code into vent, supply or reset?#
Look at what the page for your code asks first. F4 E3, AF and Check Vent ask about airflow. F4 E4 and L2 ask about the household supply. F1 E1, F3 E3, F4 E1 and F6 E1 ask only for a breaker pause. PF says the cycle was cut short by a power failure. 13456789
That order of questions is worth following, because it also tells you how much is at stake. A dryer that is built to work through a large family laundry will run on with some of these codes and stop with others, and the pages say which is which.
| Code | Maytag's reading | First thing to do | Does it keep running? |
|---|---|---|---|
| F4 E3, AF, Check Vent | Restricted air flow 12 | Lint screen, vent run, outside hood | Yes 12 |
| F4 E4, L2 | Weak or absent line voltage 34 | Both breakers, 240 volts, cord | Heater may not turn on; L2 keeps running 34 |
| F1 E1 | Reset only 5 | Breaker off 5 minutes | Not stated |
| F3 E3 | Inlet thermistor 6 | Breaker off 1 minute | Not stated |
| F4 E1 | Heater system 7 | Breaker off 1 minute | Not stated |
| F6 E1 | Communication error 9 | Breaker off 1 minute | Not stated |
| PF | Cycle cut short by a power failure 8 | Hold Start or press Power | Cycle stopped |

What does an airflow code want from me?#
Clean the lint screen, then check the vent run from the dryer to the wall for crushing or kinks, and the outside hood for lint. Maytag's F4 E3 page also asks that the run length and elbow count fall within the limits for your vent type, then to restart on a Timed Dry heated cycle. 1
If the message returns, the page says to have the entire home venting run cleaned by a venting specialist. 1 The AF or Check Vent page adds a test you can do yourself: let the dryer run for 5 to 10 minutes while you feel the air at the outside hood with your palm. If the flow feels weaker than a hair dryer's top setting, the whole run, hood included, needs its lint cleared. 2
On models with a Check Vent light, the light is only available on certain automatic cycles. It comes on during the sensing phase at the start when low airflow is detected, stays on for the whole cycle, and goes away when the cycle ends, on a touch of Power, or once the door is opened. 2 The dryer operates with the light lit, though poor airflow affects dry times and performance. 2
- 1
- 2
- 3
- 4
Maytag's advice is to clean the venting once a year or two, or earlier once dry performance has slipped. 110 Our exhaust vent glossary entry describes the part, and the entries for F4 E3 and AF carry the text.
When does the household supply come into it?#
F4 E4 and L2 both report weak or absent line voltage that stops the heater coming on. Maytag has you confirm that both breakers for the dryer are on, that the cord and terminal screws are secure, and that a 240-volt supply is present. 34
An electric dryer uses a separate 30-amp circuit with a breaker on each side of the line. One side runs the motor that turns the drum and the other runs the heating element, so a single tripped breaker can leave a dryer tumbling without heat. 34 The pages say to unplug the dryer before checking the terminal screws, and to ask an electrician about a supply that is not 240 volts. After the checks, the reset is a 5 minute breaker pause, a Timed Dry cycle and 5 minutes of watching. 34
L2 adds a detail: the dryer keeps running with the code on screen, and touching any pad clears it. 4 Our entries for F4 E4 and L2 list both pages. If the dryer will not start at all, the dryer will not start page is the better route.
Which codes only want a breaker pause?#
F1 E1 is the plainest: breaker off for 5 minutes, breaker on, a Timed Dry cycle, then one minute of watching. F3 E3 (inlet thermistor), F4 E1 (heater system) and F6 E1 (communication error) use a one minute pause and a one minute watch. 5679
The F4 E1 page adds that the problem may involve the heater or the heater relays, and the F6 E1 page says the main control board, the touchpad or the wiring may be involved. 79 Neither is something to open up at home. If the code comes back after the pause, a technician should take a look. See F1 E1, F3 E3 and F4 E1.
What does PF mean mid-cycle?#
PF reports that a power failure broke into the drying cycle. Press and hold Start to carry on with the cycle, or press Power to dismiss the message. After a recent outage, cut the dryer's breaker for 5 minutes, restore it, and keep watching for 5 more. 8
Maytag's page also says the control may show PF if the line carried unexpected electrical noise that it read as a wrong voltage, or if keys were pressed within the first 10 seconds after power came back. 8 That is why waiting a little after the lights return is worth it.
What do I note down for the visit?#
Give the code, the exact moment it appeared and what you tried. Mention how long the vent run is and how many bends it has, because airflow is the most common thing to measure.
- What was on the display, and did the dryer keep tumbling?
- Did the screen, the duct and the outside hood all look clear?
- Were both breakers on, and how long was the breaker pause?
- Did the code return at once, or only on heated cycles?
The dryer repairs we do for Maytag owners are described on our dryer page.
Sources#
- F4 E3 - Error Code - Dryer - Product Help | MaytagMaytag Product Help (producthelp.maytag.com) · dateModified 2025-11-05; PH 12811 · article text, Possible Solutions
- AF or "Check Vent" - Dryer - Product Help | MaytagMaytag Product Help (producthelp.maytag.com) · dateModified 2025-06-04; PH 12774 · article text, Possible Solutions
- F4 E4 - Error Code - Dryer - Product Help | MaytagMaytag Product Help (producthelp.maytag.com) · dateModified 2025-05-27; PH 12812 · article text, Possible Solutions
- L2 - Error Code - Dryer - Product Help | MaytagMaytag Product Help (producthelp.maytag.com) · dateModified 2025-05-27; PH 12837 · article text, Possible Solutions
- F1 E1 - Error Code - Dryer - Product Help | MaytagMaytag Product Help (producthelp.maytag.com) · dateModified 2025-04-11; PH 12789 · article text, Possible Solutions
- F3 E3 - Error Code - Dryer - Product Help | MaytagMaytag Product Help (producthelp.maytag.com) · dateModified 2026-08-19; PH 12807 · article text, Possible Solutions
- F4 E1 - Error Code - Dryer - Product Help | MaytagMaytag Product Help (producthelp.maytag.com) · dateModified 2026-08-19; PH 12810 · article text, Possible Solutions
- PF - Error Code - Dryer - Product Help | MaytagMaytag Product Help (producthelp.maytag.com) · dateModified 2025-05-27; PH 12839 · article text, Possible Solutions
- F6 E1 - Error Code - Dryer - Product Help | MaytagMaytag Product Help (producthelp.maytag.com) · dateModified 2026-08-19; PH 12815 · article text, Possible Solutions
- Long Dry Times - Dryer - Product Help | MaytagMaytag Product Help (producthelp.maytag.com) · dateModified 2025-11-05; PH 12768 · article text, Possible Solutions