On a standard dryer, F3E5 is a moisture sensor code: five consecutive loads dried without registering sensor data. Press Power to clear it, check the level and the load size, then try Automatic instead of Timed Dry. The commercial page prints only a reset.
On a standard dryer, F3E5 is a moisture sensor code: five consecutive loads dried without registering sensor data. Press Power to clear it, check the level and the load size, then try Automatic instead of Timed Dry. The commercial page prints only a reset.
On a standard dryer, F3E5 is a moisture sensor code: five consecutive loads dried without registering sensor data. Press Power to clear it, check the level and the load size, then try Automatic instead of Timed Dry. The commercial page prints only a reset.
What you can safely check
Power off before any panel comes off; lint and burnt smells mean stop and leave the dryer off.
When to call a technician
F3E5 returns after leveling, a larger load and a power cycle.
Your Maytag to-do list, saved here on this device
Safe checks, in order.
0 of 5 checks done
Illustration. Follow your model’s instructions.
Before you begin
Press Power to clear
The page says pressing the Power button clears the code and lets you restart.
Illustration. Follow your model’s instructions.
Check 2
Check the dryer is level
A dryer that is not level may keep clothes from touching the moisture sensors. Use a level and adjust the feet. The top may be curved, so measure from the cabinet edge.
Illustration. Follow your model’s instructions.
Check 3
Look at the load size
Very small loads or single items may not touch the sensors. Try a larger load.
Illustration. Follow your model’s instructions.
Check 4
Use Automatic, not Timed Dry
The page suggests an Automatic cycle instead of a Timed Dry cycle.
Illustration. Follow your model’s instructions.
Check 5
Cycle power if it persists
Breaker off for 5 minutes, back on, a timed dry cycle, and a 5-minute watch.
Does F3E5 keep coming back?
Give us the model and the checks you have run, then open your request right here.
The standard dryer page heads it “Moisture Sensor Issue” and says the code occurs when five consecutive loads are dried without registering moisture sensor data. If the problem persists, call for service.
It prints only the reset: breaker off for 5 minutes, back on, a timed dry cycle, and a one-minute watch. There is no moisture sensor text, level check or load advice, so the two sources differ in depth.
Maytag's Product Help names no model range for this code. The cited pages cover a commercial-grade residential dryer and a standard dryer. Sources: Product Help PH 11825 (commercial-grade residential dryer) and PH 12809 (dryer).