Maytag’s two F3E1 pages disagree. The standard dryer page says “Exhaust Thermistor” and a one-minute breaker reset; the commercial-grade residential page names no cause and says five minutes without power. Check which dryer you own.
Maytag dryer F3E1 / Reset only
Maytag’s two F3E1 pages disagree. The standard dryer page says “Exhaust Thermistor” and a one-minute breaker reset; the commercial-grade residential page names no cause and says five minutes without power. Check which dryer you own.
Also printed as F3E1
Maytag’s two F3E1 pages disagree. The standard dryer page says “Exhaust Thermistor” and a one-minute breaker reset; the commercial-grade residential page names no cause and says five minutes without power. Check which dryer you own.
Unplug the dryer or switch off its breaker before opening any panel, clean lint regularly, and if you smell gas leave the house and call your gas utility.
F3E1 returns after the reset and a timed dry cycle.
Your Maytag to-do list, saved here on this device

A commercial-grade residential dryer follows the five-minute page. A standard residential dryer follows the exhaust thermistor page with the one-minute reset.

One minute on the standard page, five minutes on the commercial-grade page.

Both pages tell you to start a time dry cycle after power returns.

One minute on both pages.

F3E1 names an exhaust thermistor, which reads exhaust air. A clogged lint screen or vent is our own first look; Maytag does not print it for this code.
Give us the model and the checks you have run, then open your request right here.
Book a visitA rough sketch only, because a Maytag is laid out differently from model to model. Click a highlighted part to open its photo and the matching test.

Component reference
The lint screen is the removable screen that catches lint from the air leaving a Maytag dryer.
Read the definitionThe commercial-grade residential dryer page gives only the reset: breaker off for 5 minutes, back on, a timed dry cycle, and a one-minute watch. The standard dryer page adds the heading “Exhaust Thermistor” and uses a one-minute breaker reset.
Read the supporting manualF3E3 is headed “Inlet Thermistor” and uses the same one-minute reset. F3E1 concerns the exhaust side.
Read the supporting manualF3E5 is a moisture sensor code with leveling and small-load checks and a five-consecutive-loads explanation. F3E1 has none of that.
Read the supporting manualMaytag does not say. If a hot or burning smell accompanies the code, stop and unplug the dryer or switch off its breaker.
Read the supporting manualManufacturer document
Maytag Product Help (producthelp.maytag.com)
dateModified 2025-10-21; PH 11822 / PH 11822 (commercial-grade residential dryer)
Manufacturer document
Maytag Product Help (producthelp.maytag.com)
dateModified 2026-08-19; PH 12805 / PH 12805 (dryer)
Manufacturer document
Maytag Product Help (producthelp.maytag.com)
dateModified 2026-08-19; PH 12807 / PH 12807 (dryer)
Manufacturer document
Maytag Product Help (producthelp.maytag.com)
dateModified 2025-05-27; PH 12809 / PH 12809 (dryer)
Maytag's Product Help names no model range for this code. The cited pages cover a commercial-grade residential dryer and a standard dryer. Sources: Product Help PH 11822 (commercial-grade residential dryer) and PH 12805 (dryer), with the F3E3 and F3E5 pages.
On the standard dryer page, yes: it is headed Exhaust Thermistor. The commercial page does not say.
The standard dryer page says one minute; the commercial-grade page says five.
Maytag does not say. Clean the lint screen anyway; it is routine.
Yes, a timed dry cycle, per both pages.
Maytag codes, symptoms, parts and service
F3E2 on a Maytag commercial-grade residential dryer is explained as “F3E2 - Moisture Sensor.” Switch the breaker off for a minute, then back on; schedule a visit if the code is still there.
A Maytag dryer that does nothing is usually a power, lock or latch issue before it is a broken part. An electric dryer draws on two breakers or fuses and needs 240 volts, the Control Lock may be on, and the door may look shut without latching. Check these, then book a technician.
The lint screen is the removable screen that catches lint from the air leaving a Maytag dryer. Product Help wants it cleaned after every use, because a screen blocked by lint lengthens drying time. A clogged screen or vent is also what the AF, Check Vent and F4 E3 restricted air flow messages describe.
Book a diagnostic for your model, done at the machine.
Office details, and the entry information to pass along.